Daikin Mini Split AC Indoor Unit Circuit Board Explained
Welcome to our in-depth guide on the Daikin Mini Split AC/Air Conditioner Indoor Unit Circuit Board! In this video, we'll explore the intricate details of the Daikin circuit board, including key components like thermistors, MOSFETs, and intelligent eye sensor technology. We'll cover common issues and troubleshooting tips, such as high voltage problems and component replacements. You'll also learn how the SMPS circuit and energy-saving features work to optimize your AC's performance. Whether you're an HVAC enthusiast, a technician, or a curious homeowner, this practical demonstration will help you understand and maintain your Daikin air conditioner.
💡 Support Us On Patreon 👉 bit.ly/3vMga6S
💡Subscribe to The Channel 👉 bit.ly/3vNT7s3
Social Links
💡Facebook 👉 forevertech3
💡Instagram 👉 forever_tech11
💡Twitter 👉 Forevertech3
#Daikin #MiniSplitAC #CircuitBoard #HVAC #EnergySaving #Thermistor #MOSFET #IntelligentEyeSensor #SMPSCircuit #circuit #electronics #explained
Переглядів: 414

Відео

Haier AC Indoor Control Board REPAIR Tips For Low Volt Circuit
Переглядів 1,5 тис.7 годин тому
In this video, I provide essential tips for repairing the indoor control/Circuit board of a Haier Mini Split AC/Air conditioner, focusing on low-voltage circuitry. We'll cover the 12V and 5V sections, explaining how the voltage regulator works and the role of ULN-2003 Darlington arrays in powering components like stepper motors, buzzers, and relays. I’ll show you how to check crucial voltage po...
Haier AC Indoor Control Board REPAIR Tips: SMPS Circuit Explained
Переглядів 1,9 тис.День тому
Welcome to our detailed tutorial on repairing the Haier Mini Split AC/Air Conditioner indoor control board! In this video, we'll dive into the intricacies of the Switched-Mode Power Supply (SMPS) circuit, explaining its components and functionality in simple terms. Whether you're a DIY enthusiast or a professional technician, our step-by-step guide will equip you with the knowledge to troublesh...
Avoid This Fatal Mistake When Repairing A/C Circuit Board
Переглядів 2,4 тис.День тому
Watch our must-see tips to avoid this fatal mistake when repairing your inverter mini split A/C circuit board! This video reveals a common yet critical error that can ruin your mini-split Air Conditioner circuit board after repair. Learn how to properly handle and reinstall components like the IPM and heat sink to prevent short circuits and ensure long-lasting performance. Our step-by-step guid...
Fixing Air conditioner Circuit That Won't Respond to Remote Control
Переглядів 1,4 тис.14 днів тому
Are you facing issues with your mini split air conditioner not responding to the remote control? This video provides a comprehensive, step-by-step guide to troubleshooting and fixing the circuit board problem yourself. Learn about common issues and diagnostic tips, and follow our easy-to-understand instructions to get your AC up and running again. Save money on costly service calls and gain pro...
OMG! Fix E03 Error in Your Washing Machine Fast! (No Stress)
Переглядів 94114 днів тому
Are you frustrated with your front load washer showing the E03 error code? Don't worry; we've got you covered! In this video, we'll show you a quick and easy fix to get your washing machine back to working perfectly. The E03 error means that water is not draining properly from your washer, but with our simple trick, you'll have it sorted out in no time! This guide is suitable for a wide range o...
Fixing Fujitsu Mini Split A/C Circuit Damaged By OverCurrent
Переглядів 3,3 тис.14 днів тому
When Fujitsu/O General mini split AC started acting up with an overcurrent issue, I knew I had to tackle it before it caused serious damage. It was a hot day, and the thought of being without air conditioning was stressful, but I couldn't risk making things worse. In this video, I walk you through my real-life experience of diagnosing and fixing this overcurrent problem. I share everything I le...
How to Fix FC F6 F7 F8 Errors - Revive Your Mini Split AC
Переглядів 92814 днів тому
Is your mini split air conditioner showing FC, F6, F7, or F8 error codes? Don’t let these errors ruin your cool, comfortable home! This in-depth tutorial will guide you through the troubleshooting and repair process to fix these common issues and get your AC running smoothly again. We’ll explain each error code and how it affects your Midea/Koppel/carrier/voltas/kolin/orient/Samsung inverter mi...
LG A/C Blows Up in Seconds After Powering On - Here's Why!
Переглядів 98514 днів тому
Hey everyone! I recently encountered a frustrating issue with an LG Art Cool air conditioner. Every time I switched it on, the circuit fuse blew instantly. Talk about a summer nightmare, right? 😭 In this video, I’ll walk you through the entire troubleshooting process. From identifying possible causes to checking internal components, we’ll figure out what’s happening with our beloved Mini Split ...
How to Easily Fix the EC Error Code in Your Mini Split AC
Переглядів 1,1 тис.21 день тому
Is your Carrier/Midea/Lloyd/Koppel/kolin/Voltas/super general/Dawlance/Bluestar/Samsung/Orient/BPL/Reconnect/Vester/Siemens mini split AC/Air Conditioner annoying 'EC' error code frustrating you? Don't worry. We've got you covered! This video reveals a surprising yet simple DIY fix that will have your AC running smoothly again. Watch now to discover the step-by-step process, expert tips, and co...
Washer has No Power-Here's How I Brought It Back to Life
Переглядів 99721 день тому
Struggling with a dead washing machine and a stubbornly stuck knob? You're not alone! In this video, I dive into the frustration of dealing with any LG/Samsung/Maytag or any other washer that won't even turn on and a knob that seems determined to stay put. But fear not because I'm here to share my journey of troubleshooting and fixing these common issues. First off, I'll walk you through the in...
Teardown of Automatic Water Booster Pump Switch - How it Works?
Переглядів 1,8 тис.21 день тому
In this video, we dive deep into the inner workings of an automatic water pressure control booster pump by teardown. Join us as we take apart this essential piece of equipment to uncover the mechanisms that make it function. From the motor to the pressure sensors, we explore every component and explain how they work together to boost water pressure in your home or building. If you're curious ab...
Fix Mitsubishi Mini Split AC 6 Timer Light Blinking Error
Переглядів 1,6 тис.28 днів тому
This comprehensive guide will walk you through step-by-step instructions on resolving the 6-timer light blink error on your Mitsubishi Mini Split AC unit. If you're experiencing this issue, don't worry, we've got you covered! Our troubleshooting process is designed to be easy to follow, even for beginners. Whether you're dealing with a faulty remote control, power supply issues, or other potent...
How to Recover A/C Refrigerant Back Into Compressor to Dismantle it
Переглядів 2 тис.Місяць тому
Are you looking to dismantle/remove/uninstall your Mini Split air conditioning but unsure how to safely handle the refrigerant inside? Look no further! In this comprehensive DIY guide, we'll walk you through the step-by-step process of recovering or pumping down the A/C refrigerant back into the compressor or condenser, ensuring a safe and eco-friendly dismantling process. Get ready to learn th...
IPM IC Module Failed In Fujitsu/OGeneral AC Inverter Circuit
Переглядів 2,3 тис.Місяць тому
IPM IC Module Failed In Fujitsu/OGeneral AC Inverter Circuit
Washing Machine Won't Fill Water, Takes Slow or Less Water
Переглядів 793Місяць тому
Washing Machine Won't Fill Water, Takes Slow or Less Water
These Blower Motors Won't Work in AC Circuit Board
Переглядів 1,3 тис.Місяць тому
These Blower Motors Won't Work in AC Circuit Board
How Much Power Gree Mini Split AC Consumes on "SE" Save Energy Mode
Переглядів 1,3 тис.Місяць тому
How Much Power Gree Mini Split AC Consumes on "SE" Save Energy Mode
Mini Split AC Circuit Heavily Damaged After Power Surge
Переглядів 2 тис.Місяць тому
Mini Split AC Circuit Heavily Damaged After Power Surge
How to Fix the PL Error Code in Gree Mini Split AC
Переглядів 3 тис.Місяць тому
How to Fix the PL Error Code in Gree Mini Split AC
Circuit Can't Turn ON the DC Fan Blower Motor In AC (A6 Error), Repair
Переглядів 3,2 тис.Місяць тому
Circuit Can't Turn ON the DC Fan Blower Motor In AC (A6 Error), Repair
Tool For Testing Surface Mount (SMD) Electronics Components
Переглядів 1,3 тис.Місяць тому
Tool For Testing Surface Mount (SMD) Electronics Components
Never thought that LG Display Repair could be so Complicated
Переглядів 1,6 тис.Місяць тому
Never thought that LG Display Repair could be so Complicated
You Can't Remove this Simple Connector If You Don't Do This
Переглядів 1,6 тис.Місяць тому
You Can't Remove this Simple Connector If You Don't Do This
AC Functions that Can be Used Without Remote Control
Переглядів 1,6 тис.Місяць тому
AC Functions that Can be Used Without Remote Control
Fix Hanseatic Washing Machine Error Codes: E01 E02 E03 End
Переглядів 1,4 тис.Місяць тому
Fix Hanseatic Washing Machine Error Codes: E01 E02 E03 End
A/C Circuit IGBT Driver Repair & Explanation, Other Tech Failed!!
Переглядів 12 тис.2 місяці тому
A/C Circuit IGBT Driver Repair & Explanation, Other Tech Failed!!
I Modified an AC Condenser Blower Motor to Replace the OLD
Переглядів 3,5 тис.2 місяці тому
I Modified an AC Condenser Blower Motor to Replace the OLD
No Communication Between AC Indoor & Outdoor Circuit Board Repair
Переглядів 3 тис.2 місяці тому
No Communication Between AC Indoor & Outdoor Circuit Board Repair
Inverter Mini Split AC Outdoor OverHeats & Stops After 7 Amperes
Переглядів 2,5 тис.2 місяці тому
Inverter Mini Split AC Outdoor OverHeats & Stops After 7 Amperes

КОМЕНТАРІ

  • @pradeepkumarsoni38
    @pradeepkumarsoni38 5 годин тому

    104R resistance value find please

  • @Hi-levels
    @Hi-levels 6 годин тому

    What brands do you recommend?

    • @forevertechenglish
      @forevertechenglish 6 годин тому

      Well I use Sharp my self, i have seen It is really great in performance and very efficient

  • @kamalhamdi6739
    @kamalhamdi6739 6 годин тому

    Thank you very much from informations and Nice explications khalid de Maroc Casablanca

  • @hakimullahchoudhary6845
    @hakimullahchoudhary6845 6 годин тому

    Sir i like your videos sir make detailed videos on ac circuit boards please sir

  • @Meerschaut87
    @Meerschaut87 7 годин тому

    Hi Forever Tech English, Thank you for explaining the error on the split unit. if i turn on the AC unit it starts working for about 10 minutes, after that it goes into error P4 and the compressor stops. I have done all test about the compressor wiring and tested the body short, everything is fine (also the compressor works for about 10 minutes, even the pipe starts getting ice on the surface and the indoor unit start to give cold air). I have measured the IPM and it gets +300V on the positive pin and 160V on the U, V and W Pin. Once the unit goes into error mode, the U, V and W Pin only gets a 23V. I have tried measuring the IGBT as you showed in this video: ua-cam.com/video/4IoV8I-pcT8/v-deo.htmlsi=DmGR5cOUEwL9e8AH - Negative probe on Base (Gate) and Positive on Emitter i get 0.546V - Positive on Gate and negative on Emitter i get 1.083V - Negative on Emitter and positive on Collector i get OL - Positive on Emitter and negative on Collector i get 0.464V - Negative on Gate and positive on Collector i get OL - Positive on Gate and negative on Collector i get 1.372V Is this IGBT broken or is it still oke? what else could give me this error while i don't see anything else wrong or broken? Thanks alot. With friendly greetings

    • @forevertechenglish
      @forevertechenglish 7 годин тому

      The UVW pins should have 15 volts not 160 volts

    • @Meerschaut87
      @Meerschaut87 6 годин тому

      @@forevertechenglish That is correct, i hadn't seen the dot between the 6 and 0 Now i measured 22V on every pin.

  • @user-dg9jv2dq4l
    @user-dg9jv2dq4l 7 годин тому

    شكراً جزيلاً لموضوعك

  • @godfreykizito6
    @godfreykizito6 9 годин тому

    Is it expensive to fix, covering the hole and refill the gas

  • @antonismiliakis9427
    @antonismiliakis9427 11 годин тому

    You are excellent from Greece

  • @gamechanger6436
    @gamechanger6436 12 годин тому

    Guys i fixed the E7 error by changing the batteries of the remote control. Try this before you do anything else!

    • @forevertechenglish
      @forevertechenglish 12 годин тому

      What really??? It has nothing to do with the remote batteries. The E7 is the communication error. The E7 sometimes could be shown due to voltages fluctuation, but it has nothing to do with the remote batteries.

    • @gamechanger6436
      @gamechanger6436 12 годин тому

      @@forevertechenglish I don't know why but it worked for me.

  • @b.r5198
    @b.r5198 13 годин тому

    Is the outdoor unit OK?

    • @forevertechenglish
      @forevertechenglish 13 годин тому

      The outdoor unit was fine, it had no circuit board.

    • @b.r5198
      @b.r5198 12 годин тому

      @@forevertechenglish good job

  • @sunilpennukkara2320
    @sunilpennukkara2320 16 годин тому

    Worth watching video. Well explained. Thank you very much. I am from India 👍

  • @user-ti4rd8cv1w
    @user-ti4rd8cv1w 17 годин тому

    Press play button 1st time Drum turning on clockwise direction 2nd time Drum tests medium speed 3rd time Drum tests the max speed(1000rpm) 4th time washer checking it's 1st water valve 5th time washer checking it's 2nd water valve 6th time washer checking both water valves 7th time Drum turning on anticlockwise direction 8th time washer tests the heater 9th time washer checking the drain pump and drain system 10th time washer plays a song and says you goodbye

  • @AbdulHadi-if4hk
    @AbdulHadi-if4hk 18 годин тому

    Great video

  • @user-dg9jv2dq4l
    @user-dg9jv2dq4l 18 годин тому

    Thank you for this video ❤

  • @lexeindhoven
    @lexeindhoven 19 годин тому

    Why would it switch off because that relay is overheating.. there is no way to detect that and act on that.. also the temperature was not excessive at all.. seems like you solved the problem by assembling it back.. even a loose solder is more likely

    • @forevertechenglish
      @forevertechenglish 19 годин тому

      The relay was faulty, it was heating till 50 degrees, and after that No complain from the technician who installed it back.

  • @SafirLemmings-2042
    @SafirLemmings-2042 День тому

    4:42 this is in a ghost shape so scary 😱😱💀💀💀

  • @deepajoshi9032
    @deepajoshi9032 День тому

    Galat tareka mat batao fan may paani chla gaya to😢😢😢😢

  • @biss5836
    @biss5836 2 дні тому

    LAYER.Clickbait video why did you say changed to inverter in fact it was linear compressor.STOP LAYING.

    • @forevertechenglish
      @forevertechenglish 2 дні тому

      Nope it was inverter compressor. I didn't showed the control board, this doesn't means I lied. Well the compressor I installed, you can actually check its datasheet. on the embraco's app. Go check its data. And then I think your doubts will be cleared.

  • @gilbertopatino2616
    @gilbertopatino2616 2 дні тому

    Thank you so much for awesome video👍

  • @tanukapoor2255
    @tanukapoor2255 2 дні тому

    Firstly I want to see the user of the ac

  • @marekmarowski4123
    @marekmarowski4123 2 дні тому

    super

  • @bobthebuilder7441
    @bobthebuilder7441 2 дні тому

    بعد ما عكست الاسلاك زي الفيديو ضرب معاي المكيف، اللي ضرب الموتور والمذربوود كلاهم مره وحده ، لان المكيف ما اشتغلت بعديها .. الا لما غيرت المذربورد .. وبعدها طلع لي Erorr CH10 واضطريت اغير الموتور وبعدها اشتغل .. عموما فكرة عكس الكيابل خطأ والمفروض معالجة أصل المشكلة وليس التحايل عليها

    • @forevertechenglish
      @forevertechenglish 2 дні тому

      بالمناسبة، هل يمكنني معرفة لماذا قمت بعكس أسلاك محرك المروحة؟ فهمت الآن. كان لديك مكيف هواء من LG يستخدم محرك DC، وإذا عكست الأسلاك في محركات DC، من الواضح أنها تسببت في مشكلة في الدائرة الخاصة بك. ما هو المشكلة التي واجهتك مع مكيف الهواء؟ ولماذا عكست الأسلاك دون دراسة الدائرة؟ حسنًا، إذا كنت قد اتبعت الفيديو، فأنا أقدر ذلك. لكن أعتقد أنك يجب أن تكون قد تحققت من أن محركك كان محرك DC وليس محرك AC الذي تم عرضه في الفيديو.

  • @nuwanrodrego
    @nuwanrodrego 2 дні тому

    Resistors short cct 😂😂😂😂😂😂😂😂😂

  • @user-ud8uc3px3j
    @user-ud8uc3px3j 2 дні тому

    Perfect explain ❤

  • @oscarpaezarce4849
    @oscarpaezarce4849 2 дні тому

    El mejor video ..... Muy agradecido

  • @rv10flyer84
    @rv10flyer84 2 дні тому

    Thank you so much. If you ever have time to do some Gree Sapphire Gree Livo or Fujitsu instructional videos, I would appreciate it. Those are the three I’ve sold/installed.

    • @forevertechenglish
      @forevertechenglish 2 дні тому

      I have video on Fujitsu, visit the channel for those. Soon on Gree.

  • @VenciSto
    @VenciSto 2 дні тому

    Thanks to guide! Please give a list of error codes for midea air conditioner, on/off (not inverter)!

  • @rolanddejesus8685
    @rolanddejesus8685 2 дні тому

    thank you very much for sharing your knowledge...

  • @user-gd5gj4mo4m
    @user-gd5gj4mo4m 3 дні тому

    هلوو استاذ انا تابعتك الان لانك افضل شخص يشرح على المكيف اتمنى منك ان تشرح او تعلمني كيف اتحكم بسرعه المكمبريسر المكيف انفيرتر

  • @kamalhamdi6739
    @kamalhamdi6739 3 дні тому

    Thank you very much from informations khalid from Morocco Casablanca

  • @maradallibya5791
    @maradallibya5791 3 дні тому

    Perfect❤ Would you give us more detail with the schematic of this board, low side part i meant

  • @haimt
    @haimt 3 дні тому

    HI, no the zero ohm resistors are not ruling as fuses, it on this board at act as a jumpers, this is one side complex board, it is not possible to design the board without them!

    • @forevertechenglish
      @forevertechenglish 2 дні тому

      You are right that it act as jumpers, if you install a copper jumper it wattages will be very high and bear more current than usual. But if we use zero ohms resistors, they are based on wattages capacity, for example if we use 1/4 watt capacity of zero resistors. It will not allow more current then its capacity, if more current tries to pass through this resistor, it will be burned and the purpose of this resistor will be achieved to save the further components.

    • @user-gd5gj4mo4m
      @user-gd5gj4mo4m 2 дні тому

      السلام عليكم صديقي كيف يمكنني ان اتحكم بسرعه الكمبريسر من خلاق الحساسات

  • @nts4906
    @nts4906 3 дні тому

    Thank you for this. ❤

  • @chandarasena
    @chandarasena 3 дні тому

    Thanks for your clear instruction.

  • @The_Sweep_Life
    @The_Sweep_Life 3 дні тому

    Shouldnt you purge the valve after you puncture it and before you connect it to the system? Seems like there could be some air contamination in there.

  • @pyrojason
    @pyrojason 3 дні тому

    What was the original reason for checking the board?

    • @forevertechenglish
      @forevertechenglish 3 дні тому

      The IPM was faulty in this board, I will upload that video soon.

    • @pyrojason
      @pyrojason 3 дні тому

      @@forevertechenglish So you had to go through one IPM initially, and then the next one due to thermal damage?

    • @forevertechenglish
      @forevertechenglish 3 дні тому

      Yes.

  • @bobthebuilder7441
    @bobthebuilder7441 3 дні тому

    بدلت الكيابل زي الفيديو وضربت معاي لوحة البورد .. 😢

    • @forevertechenglish
      @forevertechenglish 3 дні тому

      أي كابلات قمت باستبدالها، وما نوع المحرك الذي لديك؟ هل قمت بمراجعة مخطط الأسلاك الخاص بالمحرك قبل اتباع الفيديو؟ ما نوع محرك النفخ الذي لديك؟ وأيضًا، ما هي العلامة التجارية لجهاز التكييف الخاص بك؟

    • @forevertechenglish
      @forevertechenglish 3 дні тому

      إذا احترقت لوحة الدائرة، فهذا يعني أنك ارتكبت خطأً في التوصيلات، أو أنك لم تفحص لوحة التحكم أو المحرك بشكل صحيح لتفهم تكوين الأسلاك في لوحتك. هذا مهم لأن كل شركة تصمم تكوين الأسلاك بطريقتها الخاصة.

    • @bobthebuilder7441
      @bobthebuilder7441 3 дні тому

      lg dual inverter

    • @forevertechenglish
      @forevertechenglish 2 дні тому

      Oh was it a brushless Dc motor or a Pg Motor?

    • @bobthebuilder7441
      @bobthebuilder7441 2 дні тому

      اللي ضرب معاي الموتور والمذربوود كلاهم مره وحده ، لان المكيف ما اشتغلت بعديها .. الا لما غيرت المذربورد .. وبعدها طلع لي Erorr CH10 واضطريت اغير الموتور وبعدها اشتغل .. عموما فكرة عكس الكيابل خطأ والمفروض معالجة أصل المشكلة وليس التحايل عليها

  • @bobthebuilder7441
    @bobthebuilder7441 3 дні тому

    I switch the cables and it burned out the circuit board 😢

  • @Bizija123
    @Bizija123 3 дні тому

    That was better than a hollywood movie, with a sad plot twist. LOL. So moral of the story, don't try to repair this utter garbage. Replace and go.

  • @pcsplus2011
    @pcsplus2011 4 дні тому

    These coils are junk and leak all the time

  • @user-eh7ld4xu9b
    @user-eh7ld4xu9b 4 дні тому

    Hi friend.i have bosch kfr35w ac inverter and E1 error.i cant see clock signal on optocoupler and cant see eprom clock and data signal.crystal works good.what can i do ? Is it software problem ?

  • @kxtreme1942
    @kxtreme1942 4 дні тому

    Those AC units are junk after 4-5 years. This is a crime!

  • @nanibelloua4962
    @nanibelloua4962 4 дні тому

    How to make analyzer

  • @saijuakshaya1983
    @saijuakshaya1983 4 дні тому

    Well experience sir i appreciate

  • @abdulwaheededitz
    @abdulwaheededitz 5 днів тому

    if you run your ac on 28 to 30 temperature .you get more saving then this bullshit SE option

  • @user-hq4zy5kc4r
    @user-hq4zy5kc4r 5 днів тому

    Thanks

  • @redlion9199
    @redlion9199 5 днів тому

    I have been in the industry for 59 years, and would never use flammable refrigerant... It's insane!!!!

  • @thomasoconnor-cs3ee
    @thomasoconnor-cs3ee 5 днів тому

    So when you join the 2 points of the optocoupler the thermostat doesnt need to be connected?

  • @jaibihar9813
    @jaibihar9813 5 днів тому

    Shows so much of dirt over and again. Blowing own trumpet.

  • @Xuomiredmi10
    @Xuomiredmi10 5 днів тому

    Thank you very much doctor, very excellent work, your friend from Algeria